                      | pH electrode of lab | type | measure range | applicable temperature | application(it can be add 
                        temperature compensation element according to client's 
                        need.) | 
                     
                      |  | E-201 | 0~14pH | 0~60℃ | The crust of PC be able to endure 
                        hit,gelatin KC1 electrolytic liquid dispense with complementarity 
                        ,in order laboratory and locale general use. | 
                     
                      | E-210C | 0~14pH | 0~60℃ | The crust of PC be able to endure hit,it 
                        can supplement electrolytic liquid, in order laboratory 
                        and locale general use, superior testing accuracy. | 
                     
                      |  | SP300 | 0~14pH | 0~80℃ | vitreous material,using in measure of laboratory 
                        precision pH, The measure solution contains organic impregnant 
                        and occasion of superior temperature.it can complement 
                        KC1 electrolytic liquid. | 
                     
                      |  | SP600 | 0~14pH | 0~80℃ | The crust of PC be able to endure hit,gelatin 
                        KC1 electrolytic liquid dispense with complementarity, 
                        the sensitive velum of special plan.it is applicable to 
                        determine surface pH value of paper making,piece goods, 
                        skin,fruit ect. | 
                     
                      |  | 
                     
                      | ORP electrode of lab | type | direction electrode | applicable temperature | application | 
                     
                      |  | SO100 | ф6×2.5mm platinic golden loop
 | -5~60℃ | The crust of PC be able to endure hit,it 
                        can supplement electrolytic liquid, in order laboratory 
                        and locale general use to measure the oxidable reductive 
                        electricity of solution. it use to reductive medium currently. | 
                     
                      |  | SO300 | ф6×2.5mm platinic golden loop
 | -5~100℃ | vitreous material, in order laboratory and 
                        locale general use to measure the oxidable reductive electricity 
                        of solution.The measure solution contains organic impregnant 
                        and occasion of superior temperature. it use to reductive 
                        medium currently.it can complement KC1 electrolytic liquid. | 
                     
                      |  | 
                     
                      | ion selective electrode | type | measure range | applicable temperature | application | 
                     
                      |  | 6801 natrium electrode | 0~6pNa | 20~40℃ | It is use in the department 
                        of thermoelectric mill,paper mill,hospital and aquaculture 
                        ect. | 
                     
                      | 701 complex natrium electrode | 0~6pNa | 20~40℃ | The complex electrode is made of natrium 
                        electrode and reference electrodes,use expediently.It 
                        is use in the department of thermoelectric mill,paper 
                        mill,hospital and aquaculture ect. | 
                     
                      | pF-1A fluorin 
                        electrode | 10-1~10-6M 
 | 5~45℃ | It is able to determine direction 
                        electrode of fluorin ion strength in solution.It is applicable 
                        to light industry,seawater and environment protection 
                        ect. | 
                     
                      |  | pF-1B complex fluorin electrode | 10-1~10-6M | 5~45℃ | The complex electrode is made of fluorin 
                        electrode and reference electrodes,use expediently.It 
                        is able to determine the strength of fluorin ion in solution. 
                        It is applicable to light industry,seawater and environment 
                        protection ect | 
                     
                      |  | pNH3-1 ammonia 
                        electrode | 10-1~ 5×10-6M
 | 5~45℃ | The ammonia electrode is made up of plane 
                        pH complex electrode ventilate velum.It is able to determine 
                        the content of ammonia in solution.It is applicable to 
                        fertilizer,main-water plant and aquaculture ect. | 
                     
                      |  | pCl-1 chlorin electrode | 10-1~ 5×10-5M
 | room temperature | The chlorin electrode is ion selective electrode 
                        with AgCl-Ag2S sensitive velum.It is able to measure the 
                        strength of chlorin ion in solution.It is applicable to 
                        foodstuff, alcohol,drink,medicament and sewage ect. | 
                     
                      | PCa-1 calcium electrode | 10-1~10-5M | room temperature | The chlorin electrode is ion selective electrode 
                        with PVC velum.It is able to measure the strength of calcium 
                        ion in solution.It is applicable to the water quality 
                        of boiler,road and biochemistry ect. | 
                     
                      |  | 
                     
                      | conductance electrode of 
                        lab | type | constant of conductance pool | measure range | application(it can be add 
                        temperature compensation element according to client's 
                        need.) | 
                     
                      |  | DJS-0.1 | 0.1±0.02 | 0.5~200μ S | The conductance electrode is 
                        measure element of conductivity meter.It is use to measure 
                        conductivity of solution. it can be add temperature compensation 
                        element to increase the measure precision according to 
                        client's need.and it is provided with the capability of 
                        temperature compensation.It is mostly applicable to electricity 
                        factory,semiconductor,pharmacy,pure-water processing,chemical 
                        industry,foodstuff drink,paper makingand sewage-water 
                        processing ect. | 
                     
                      | DJS-1 | 1±0.2 | 5~10,000μ S | 
                     
                      | DJS-10 | 10±2 | 500~200,000μS | 
                     
                      |  | 
                     
                      | industrial conductance electrode | type | constant of conductance pool | measure range | application(it can be add 
                        temperature compensation element according to client's 
                        need.) | 
                     
                      |  | GC100 | 0.01 | 0.05~20μS | It is mostly applicable to electricity 
                        factory,semiconductor,pharmacy,pure-water processing,chemical 
                        industry,foodstuff drink,paper makingand sewage-water 
                        processing ect. | 
                     
                      | GC200 | 0.1 | 0.5~200μS | 
                     
                      | GC300 | 1 | 5~10,000μS | 
                     
                      |  | 
                     
                      | industrial pH electrode | type | constant of conductance pool | measure range | application(it can be add 
                        temperature compensation element according to client's 
                        need.) | 
                     
                      |  | GP100pH complex electrode 
                        (sewage) | 0~14pH | 5~60℃ | Its ensitive ball-vesicle is semicircular.and 
                        is easy clear. It is not easy jammed.and gelate electrolyte,not 
                        need complement KCL.It is mostly used in industry and 
                        environment protection ect. | 
                     
                      |  | GP400pH complex electrode 
                        (pure-water) | 2~12pH | 0~60℃ | The complex electrode is not need complement 
                        KCL.It is mostly used in supply water of boiler and concentrated 
                        water of smoke ect. | 
                     
                      | GP500 complex electrode of 
                        high temperature strong acid | 0~9pH | 20~100℃ | It is made of reference electrodes with 
                        special sensitive glass-velum and capillary Ag/AgCl of 
                        use chronically.It is applicable to the medium of high 
                        temperature strong acid. | 
                     
                      |  | GP700 pH complex electrode 
                        of endure alkali | 3~14pH | 5~60℃ | It is made of reference electrodes with 
                        special sensitive glass-velum and capillary Ag/AgCl of 
                        use chronically.It is applicable to the special system 
                        of endure alkali. | 
                     
                      |  | GP800pH three complex electrode` | 0~14pH | 0~80℃ | The three complex electrode is made up of 
                        glass-electrode,reference electrodes and temperature-electrode.It 
                        is easy used. | 
                     
                      |  | 
                     
                      | industrial ORP electrode | type | direction electrode | applicable temperature | application | 
                     
                      |  | GO100 | ф6×2.5mm platinic golden loop | 0~100℃ | It is mostly used in industry and environment 
                        protection ect. | 
                  
                  
                    
                    
                      |  | 
                     
                      | product name 
 | type | product purpose | 
                     
                      | taper pH glass-electrode | KL-851 | It is applicable to determine pH original 
                        value in soil,water-system and vegetable ect. | 
                     
                      | full solid state taper pH electrode | KL-842 | It is applicable to determine pH original 
                        value in soil,water-system and vegetable ect. | 
                     
                      | flat shape pH electrode | KL-741 | It is applicable to determine pH original 
                        value in soil,water-system and vegetable ect. | 
                     
                      | minitype pH glass-electrode | KL-869 | It is applicable to determine pH value in 
                        dram sample of ocean,water quality,plant,chemical industry 
                        and sanitation ect. | 
                     
                      | minisize spinal shape pH electrode | KL-8170 | It is applicable to determine pH value in 
                        plant and sanitation ect. | 
                     
                      | minisize conglobate pH electrode | KL-8170 | It is applicable to determine pH value in 
                        plant and sanitation ect. | 
                     
                      | minisize flat shape pH electrode | KL-8170 | It is applicable to determine pH value in 
                        plant and sanitation ect. | 
                     
                      | plumbago electrode | KL-099 | It is applicable to determine direction 
                        electrode in reductive matter of soil,dirt and water-system 
                        ect. | 
                     
                      | taper conductance electrode | KL-910 | It is applicable to determine conductance 
                        of soil and paddy field ect. | 
                     
                      | tiny conductance electrode | KLS-2 | It is applicable to determine conductance 
                        value in soil,the leaf and fruit of plant and other dram 
                        sample ect. | 
                     
                      | tiny crop conductance electrode | KLS-3 | It is applicable to determine conductance 
                        value in soil,the leaf and fruit of plant and other dram 
                        sample ect. | 
                     
                      | minitype PNa electrode | KL-8612 | It is used in half of microanalysis. | 
                     
                      | oxygen electrode | KL-9801 | It is applicable to determine the content 
                        of oxygen in soil,water quality,environment protection 
                        and sanitation ect. | 
                     
                      | ammonia electrode | KL-873 | It is applicable to determine the content 
                        of nitrogen in soil,fertilizer and water quality ect. | 
                     
                      | kalium electrode | KL-811 | It is applicable to determine the content 
                        of kalium in soil, water-system and blood ect. | 
                     
                      | nitric acid radical electrode | KL-813 | It is applicable to determine the nitrogen 
                        in soil, fertilizer, water quality and vegetable ect. | 
                     
                      | sulfur electrode | KL-731 | It is applicable to determine the sulfur 
                        in soil,water quality,environment protection,petrifaction 
                        and take pictures ect. | 
                     
                      | iodine electrode | KL-732 | It is applicable to determine the iodine 
                        in soil and water quality ect. | 
                     
                      | bromine electrode | KL-733 | It is applicable to determine the bromine 
                        in soil and water quality ect. | 
                     
                      | medicine pH electrode | KL-9403 | It is applicable to determine pH value of 
                        blood. | 
                     
                      | medicine chlorin electrode | KL-9404 | It is applicable to determine chlorin value 
                        of blood. | 
                     
                      | medicine kalium electrode | KL-9405 | It is applicable to determine the content 
                        of kalium in blood. | 
                     
                      | medicine natrium electrode | KL-9406 | It is applicable to determine the content 
                        of natrium in blood. |